Thermodynamic limitations on the temperature sensitivity of cell-membrane ion channels: Trouble with enthalpy uncertaintyстатья
Информация о цитировании статьи получена из
Web of Science,
Scopus
Статья опубликована в журнале из списка Web of Science и/или Scopus
Дата последнего поиска статьи во внешних источниках: 6 декабря 2018 г.
Аннотация:Energy exchange between a thermodynamic ensemble of heat- and cold-activated cell-membrane ion channels and the surrounding heat reservoir is shown to impose fundamental limitations on the
performance of such channels as temperature-controlled gates for thermal cell activation. Analysis of unavoidable thermodynamic internal-energy fluctuations caused by energy exchange between the ion channels and the heat bath suggests that the resulting enthalpy uncertainty is too high for a robust ion-current gating by a single ion channel, implying that large ensembles of ion channels are needed for thermal cell activation. We argue, based on this thermodynamic analysis, that, had thermosensitive cell-membrane ion channels operated individually, rather than as large ensembles, robust thermal cell activation would have been impossible because of thermodynamic fluctuations.