Аннотация:Cognitive tests on representative groups of freely behaving transgenic mice are shown to enable a quantitative characterization of reconnectable implantable fiber-optic neurointerfaces for optogenetic neurostimulation. A systematic analysis of such tests provides a robust quantitative measure for the cognitive effects induced by fiber-optic neurostimulation, validating the performance of fiber-optic neurointerfaces for long-term optogenetic brain stimulations and showing no statistically significant artifacts in the behavior of transgenic mice due to interface implantation.