Microwave frequency standard on Hg-199 ions for space stations and vehiclesстатья
Информация о цитировании статьи получена из
Scopus
Статья опубликована в журнале из списка Web of Science и/или Scopus
Дата последнего поиска статьи во внешних источниках: 20 февраля 2024 г.
Аннотация:In the paper the design of a magnetic trap for low mass-dimensional microwave frequency standards is presented. The dependencies between the number of registered photons by PMT and magnetic field values are established. The new algorithm for optical processing is developed. For different designs of microwave standard on 199Hg+ ions the results comparison of experimental Allan deviation researches is performed.